Goto

Collaborating Authors

 robotic catheter


Adjusting Tissue Puncture Omnidirectionally In Situ with Pneumatic Rotatable Biopsy Mechanism and Hierarchical Airflow Management in Tortuous Luminal Pathways

Lin, Botao, Zhang, Tinghua, Yuan, Sishen, Wang, Tiantian, Wang, Jiaole, Yuan, Wu, Ren, Hongliang

arXiv.org Artificial Intelligence

In situ tissue biopsy with an endoluminal catheter is an efficient approach for disease diagnosis, featuring low invasiveness and few complications. However, the endoluminal catheter struggles to adjust the biopsy direction by distal endoscope bending or proximal twisting for tissue sampling within the tortuous luminal organs, due to friction-induced hysteresis and narrow spaces. Here, we propose a pneumatically-driven robotic catheter enabling the adjustment of the sampling direction without twisting the catheter for an accurate in situ omnidirectional biopsy. The distal end of the robotic catheter consists of a pneumatic bending actuator for the catheter's deployment in torturous luminal organs and a pneumatic rotatable biopsy mechanism (PRBM). By hierarchical airflow control, the PRBM can adjust the biopsy direction under low airflow and deploy the biopsy needle with higher airflow, allowing for rapid omnidirectional sampling of tissue in situ. This paper describes the design, modeling, and characterization of the proposed robotic catheter, including repeated deployment assessments of the biopsy needle, puncture force measurement, and validation via phantom tests. The PRBM prototype has six sampling directions evenly distributed across 360 degrees when actuated by a positive pressure of 0.3 MPa. The pneumatically-driven robotic catheter provides a novel biopsy strategy, potentially facilitating in situ multidirectional biopsies in tortuous luminal organs with minimum invasiveness.

  Country:
  Genre: Research Report (0.64)
  Industry: Health & Medicine > Diagnostic Medicine > Biopsy (1.00)

Robust Path Planning via Learning from Demonstrations for Robotic Catheters in Deformable Environments

Li, Zhen, Lambranzi, Chiara, Wu, Di, Segato, Alice, De Marco, Federico, Poorten, Emmanuel Vander, Dankelman, Jenny, De Momi, Elena

arXiv.org Artificial Intelligence

Navigation through tortuous and deformable vessels using catheters with limited steering capability underscores the need for reliable path planning. State-of-the-art path planners do not fully account for the deformable nature of the environment. This work proposes a robust path planner via a learning from demonstrations method, named Curriculum Generative Adversarial Imitation Learning (C-GAIL). This path planning framework takes into account the interaction between steerable catheters and vessel walls and the deformable property of vessels. In-silico comparative experiments show that the proposed network achieves smaller targeting errors, and a higher success rate, compared to a state-of-the-art approach based on GAIL. The in-vitro validation experiments demonstrate that the path generated by the proposed C-GAIL path planner aligns better with the actual steering capability of the pneumatic artificial muscle-driven catheter utilized in this study. Therefore, the proposed approach can provide enhanced support to the user in navigating the catheter towards the target with greater precision, in contrast to the conventional centerline-following technique. The targeting and tracking errors are 1.26$\pm$0.55mm and 5.18$\pm$3.48mm, respectively. The proposed path planning framework exhibits superior performance in managing uncertainty associated with vessel deformation, thereby resulting in lower tracking errors.